ICP2000 Type:ICP2000

ICP2000 Type:ICP2000

  • NH00372
Giá: Liên hệ

 

Product description, Technical parameters and configuration

Instrument introduction

ICP-2000 Inductively Coupled Plasma Spectrometers can detect approximately 70 trace to constant elements in different materials. They are widely used in scientific research Institutes, colleges, and other industry enterprises related to the fields such as geology, metallurgy, rare earth materials, electro-plating, cement, petroleum, chemical engineering, environmental detection, non-ferrous metals, medical science, food and agriculture.

Performance characteristics

Simultaneous measurement of multi elements
Low detection limit: 0.1-10ppb, and even lower 
Wide density linear range, 5-6 orders of magnitude
Less chemical interference, maximum accuracy, RSD≤2% 
High analysis speed,low cost

Technical specifications

RF Generator Specifications 
Circuit type: inductively feedback self-oscillation circuit, coaxial cable transmission, matched tuning, power feedback close-loop auto-control
Working frequency: 40MHz±0.05% 
Frequency stability: <0.1%
Power output: 800W-1200W
Power output stability: <0.3%
Intensity of electromagnetic leakage: electric filed intensity in 30cm distance to the body: E:<2V/m
High Frequency Box
High Frequency Box excites very stable plasma torch by exploiting the inductively feedback self-oscillation circuit. The circuit is transmitted by coaxial cable, matchingly tuned and implements close-loop auto-control by means of power feedback (National Patented Invention). Industrial argon can be used in this kind of generator, which not only makes the lighting the ICP torch easy but also saves the cost of highly purified argon. 
Match box
The high performance match box is composed of vacuum ceramic adjustable capacitors and gas adjustable capacitors, which allows it to reach the best match state and achieve maximum effective output on load coils. 
Directional coupler
The stability of power output is achieved by controlling the anode voltage of oscillation valve after the power signals are sent out of the directional coupler and get amplified by the amplifier. 
Sample introduction system specifications:
Inner diameter of output coils: 25 mm, 3 coils 
Torch: three concentric torches, outer diameter 20 mm, quartz 
Outer diameter of coaxial nebulizer: 6mm
Outer diameter of double-pass spray chamber: 34mm
Specifications of Ar flowmeter and carrier gas pressure gauge: 
Plasma gas flowmeter: (100-1000)L/h (1.6-16L/min)
Auxiliary gas flowmeter(10-100)L/h (0.16-1.66L/min)
Carrier gas flowmeter10-100)L/h (0.16-1.66L/min)
Carrier gas pressure stabilization valve (0-0.4MPa) 
Cooling water: Water temperature: 15-25℃ Flow rate >5L/min Water pressure: >0.1MPa Resistivity>1MΩ 
Technical Specifications of Optical System
Optical path: Czerny-Turner 
Focal length: 1000mm
Grating specification: Ion Beam Etching Holographic Grating; The etching density is 3600 grooves/mm; the etching area is 80*110 mm.
(Alternative 2400 grooves/mm; etching area: 80*110mm)
Reciprocal linear dispersion rate: 0.26nm
Resolution: ≤ 0.008nm
Scan wavelength range: 
3600 grooves/mm scan wavelength range: 195—500 nm
2400 grooves/mm scan wavelength range: 195—800 nm 
Minimum pace of stepper motor drive: 0.0006nm
Exit and entrance slit: 20μm
Speculum specifications: (78×105×16)mm 
Lensφ30,1:1 imaging
Thermostatic device for optical system: 32℃±1℃

Application fields

Petrochemical engineering 
Minerals
Metallurgy
Geography
Medicine safety
Lab research 
Environment monitoring
Food safety

Bình luận

MÁY ĐO CHUẨN RoHS 2.0 THẾ HỆ MỚI SUPER 9200

0 ₫

MÁY ĐO CHUẨN RoHS 2.0 THẾ HỆ MỚI MODEL SUPER 9200

Mua hàng

Máy đo chuẩn RoHS phiên bản mới Model: EDX8000

0 ₫

Theo chuẩn: NIST USA
Thời gian cung cấp: Có sẵn
Điều khoản thanh toán: Tiền mặt / CK
Mua hàng